Field Programmable
Functions
Single
Mode
One combination is required to open lock, Manager
(User 1) or User 2. Manager must add and enable User 2.
Dual Custody Mode
Both User 1 & User 2 combinations are required to open lock.
Super Master Control
A 6-digit code is used to reset lock to Factory Defaults [optional].
All functions are field programmable. A Wrong Try
Lockout Penalty of 3 minutes will start after 5 wrong combinations
are entered.
Accessories
Relock Adapter Plate
Universal Relocker Plate
12” Cable (STD)
18” Cable
Black Faceplate (LCLX only)
Satin Aluminum Faceplate (LCLX only)
Satin Brass Faceplate (LCLX only)
Certifications
UL Type 1 listed
VdS Pending
EnV 1300 Pending |
|
Mechanical
Specifications
Lock Mechanism
Case: 2-piece lock case & cover with
yellow chromate conversions coating for corrosion resistance.
Electro-mechanical solenoid operation tested to 25,000 cycles. All mounting hardware
included.
LCLX
Housing: Lexan with choice of faceplate in Black (STD), Satin
Aluminum, or Satin Brass.
LCMX
Housing: Die cast Zamac with Bright Brass Finish.
LCLX / LCMX
Keypad: 12 button tactile membrane keypad with 1 LED
and audible tones for communications.
Slide Bolt: Bolt Work is required
for Slide Bolt Retraction. Does not require a spindle for operation.
Applications
The UL type 1 rating allows many different application types.
The Key Pad Housing can be mounted away from lock body for
added security. For retrofit applications,
the Slide Bolt Lock body can be mounted over the spindle hole. Bolt works
must be present to drive slide bolt. |
|
Electronic
Specifications
Power Unit: Solenoid operation securely controlled by a state of the art Flash
Micro Processor.
Power: PowerSaver™ circuit
utilizes a 9-volt alkaline battery where power lasts virtually
for the shelf life of the battery.
Memory: Programmable nonvolatile
Flash Memory for 1 or 2 users.
Environmental Specifications
Temperature: 32F (0C) to 120F (49C). Exposure time of at least
4 hours (UL #2058 section #22.1). Humidity: 86F (30C) and 85% relative humidity
for 24 hours (UL #2058 section #23).
Cycle Testing: 25,000 cycles at a rate of
not more than 15 cycles per minute. Exceeds UL requirement of 10,000
cycles (UL #2058 section #25).
Door Preparation
Lock designed to meet industry standard mounting patterns. Slide Bolts can be
mounted in all 8 positions. |